A Guide to Building Regulations for Insulation

Over the past few years the parts of the building regulations that relate to energy efficiency, have been revised several times in line with the need for increased energy efficiency, and to reduce the impact buildings have on global warming. This has meant significant changes to the thickness of insulation required for buildings.

Part L1 & L2 (2002) were updated in December 2005. The main changes will relate to different methodologies, that will be used for new buildings and existing buildings.

Existing Buildings & Conversions

The regulations specify "elemental U-values" for the various parts of a building. In simple terms, this means that there are specified U-values for walls, floors and the various types of roof construction. The previous and new (current) U-values (in W/m2.k) are detailed in the table below

Element Previous Requirement Current Requirement
Walls 0.35 0.27
Floors 0.25 0.22
Roofs with ceiling 0.16 0.13
Pitched Roofs (loft conversions) 0.30 0.20
Flat roofs 0.25 0.16

How does this affect a conversion or a change-of-use?

In effect, extensions and conversions will have to comply with the regulations, and this will mean that some parts of a building e.g. a converted loft in an existing house, will have to peform at a higher level than the rest of the house.

The only way to achieve these higher standards will be to use thicker or higher performance insulation materials.

How do I determine what the U value will be with a specific thickness of insulation? Follow this link to take advantage of our free U-value calculation service

New Buildings

For new buildings, the elemental method is to be eliminated in favour of a Standard Assessment Procedure (SAP) rating for the building as a whole. In other words, compliance will be based on a more wholistic approach based on the energy and carbon performance of the whole building. For new builds we strongly recommend that you seek guidance from your architect in this regard.



Reference: Office of the Deputy Prime Minister, Building Regulations Draft approved document Part L1B (2006). Please note that this information is provided in good faith and may be subject to change. Please refer to your local planning officer or Architect before beginning renovation work.

 
insulating an 			agricultural barn
insulating a loft with spray 						foam
insulating narrowboats and 						yachts
insulating barn conversions
condensation prevention in 			warehouses
roof insulation with Handi-foam
insulating between timber studs in a wooden frame 			construction